0
Cart
0

    Cart is Empty!! Add some products in your Cart

Total:
0.00
View cart Check out

Product Details

6 Core Armored OM3 Cable

0 ★

160.00৳ 0% Off

brand :
Sold By
Genius Store

86

Total Items
Contact Seller
Optical Cable for Indoor(GJFJV) Cable design: Cross-sectional Drawing of Cable Cable Description: Indoor cable. 2〜12 fiber, Φ550μm, steel wire, tight buffer fiber, layer of Kevlar yarn, LSZH Jacket. Certificates: ISO9002, SGS, ROHS, ULE329066, REACH Characteristics: Good mechanical and environmental characteristics; Soft, flexible, easy to splice, and with big capacity data transmission; Flame retardant characteristics meets the requirements of relevant standards Fiber style Unit SM G652D MM 50/125 MM 62.5/125 OM3, OM4-300 50/125 condition nm 1310/1550 850/1300 850/1300 850/1300 attenuation dB/km ≤0.36/0.23 ≤3.0/1.0 ≤3.0/1.0 ≤3.0/1.0 Dispersion 1310nm Ps/(nm*km) ≤18 ..... ..... ..... 1550nm Ps/(nm*km) ≤22 ..... ..... ..... Bandwidth 850nm MHZ. KM ..... ≧400 ≧400 ≧500 1300nm MHZ. KM ..... ≧800 ≧800 ≧1500 Zero dispersion wavelength nm ≧1302, ≤1322 ..... ..... ..... Zero dispersion slope nm ≤0.091 ..... ..... ..... PMD Maximum Individual Fiber ≤0.2 ..... ..... ..... PMD Design Link Value Ps(nm2*km) ≤0.08 ..... ..... ..... Fiber cutoff wavelength λc nm ≧1180, ≤133 0 ..... ..... ..... Cable cutoff wavelength λcc nm ≤1260 ..... ..... ..... MFD 1310nm um 9.2±0.4 ..... ..... ..... 1550nm um 10.4±0.8 ..... ..... ..... Numerical Aperture (NA) ...... 0.200±0.015 0.275±0.015 0.200±0.015 Step (mean of bidirectional measurement) dB ≤0.05 ≤0.10 ≤0.10 ≤0.10 Irregularities over fiber length and point discontinuity dB ≤0.05 ≤0.10 ≤0.10 ≤0.10 Difference backscatter coefficient dB/km ≤0.03 ≤0.08 ≤0.10 ≤0.08 Attenuation uniformity dB/km ≤0.01 ....... ....... ....... Core diameter um ...... 50±1.0 62.5±2.5 50±2.5 Cladding diameter um 125.0±1.0 125.0±1.0 125.0±1.0 125.0±1.0 Cladding non-circularity % ≤1.0 ≤1.0 ≤1.0 ≤1.0 Coating diameter um 242±7 242±7 242±7 242±7 Coating/chaffinch concentrically error um ≤12.0 ≤12.0 ≤12.0 ≤12.0 Coating non circularity % ≤6.0 ≤6.0 ≤6.0 ≤6.0 Core/cladding concentricity error um ≤0.6 ≤1.5 ≤1.5 ≤1.5 Curl(radius) um ≤4 ..... ..... ..... Cable construction details: Technical Parameters: No Out Diameter Tight buffer Weight Min. allowable Tensile Strength(N) Min. allowable Crush Load (N/100mm) Min. Bending Radius (MM) Storage Diameter temperature Core (MM) (MM) (KG) short term long term short term long term short term long term (℃) 2 3 0.6 1000 300 1000 500 20D 10D 40 4 4 0.6 1000 300 1000 500 20D 10D 40 6 4.5 0.6 1000 300 1000 500 20D 10D 40 8 5 0.6 1000 300 1000 500 20D 10D 40 12 6 0.6 1000 300 1000 500 20D 10D 40 24 10.5 0.6 1000 300 1000 500 20D 10D 40 Testing Lab: No Device name No Device name 1 Optical time domain reflectometer (OTDR) 8 GNZV Cable Torsion Testing Machine 2 Fiber Polarization Mode Dispersion 9 GQNV Cable Flexing Testing Machine 3 Fiber Dispersion, Strain Tester 10 GJRV Cable Winding Testing Machine 4 High Low Temperature Test Chamber 11 GZDV Cable Vibration Testing Machine 5 Cable Impact Testing Machine 12 Cable Water Penetration Test 6 Cable Squash Tensile Testing Machine 13 Fusion Splicer 7 GWQV Cable Bending Tester 14 Cable Water Penetration Test Rig Fiber Optic Cable Mechanical Performance Testing Laboratory: 1. Main Testing Type: Precision Test and Mechanical Test. 2. Precision Testing Machine: EXFO OTDR, EG&G PMD-440, CD-400. 3. Mechanical Performance Testing: Temperature, Impact, Tensile, Bending, Torsion, Flexing, Winding, Vibration, Water Penetration, Fusion Splicer, Water Penetration. Application: • Used in pigtails and patch cords; • Used in optical connections in optical communication equipment rooms and optical distribution frames; • Used in optical connections in optical apparatus and equipment. Cable marking: The cable sheath shall be marked with white characters at intervals of one meter with following information: 1 2 3 4 5 6 Brand name Fiber type and counts Cable type Name of manufacturer Country of origin Length marking Part Number: Items Name Part Number 6 core MM (50/125um) (OM3) Indoor Type Armored cable 6F-GJFJV-O3-AT 6 core MM (50/125um) (OM4) Indoor Type Armored cable 6F-GJFJV-O4-AT

To Comment

No Review Found.


To Review

Related Products

Sign up to newslatter

No Excuse Make Effort