Optical Cable for Indoor(GJFJV)
Cable design:
Cross-sectional Drawing of Cable
Cable Description:
Indoor cable.
2〜12 fiber, Φ550μm, steel wire, tight buffer fiber, layer of Kevlar yarn, LSZH Jacket. Certificates: ISO9002, SGS, ROHS, ULE329066, REACH
Characteristics:
Good mechanical and environmental characteristics;
Soft, flexible, easy to splice, and with big capacity data transmission;
Flame retardant characteristics meets the requirements of relevant standards
Fiber style Unit SM G652D MM 50/125 MM 62.5/125 OM3, OM4-300 50/125
condition nm 1310/1550 850/1300 850/1300 850/1300
attenuation dB/km ≤0.36/0.23 ≤3.0/1.0 ≤3.0/1.0 ≤3.0/1.0
Dispersion 1310nm Ps/(nm*km) ≤18 ..... ..... .....
1550nm Ps/(nm*km) ≤22 ..... ..... .....
Bandwidth 850nm MHZ. KM ..... ≧400 ≧400 ≧500
1300nm MHZ. KM ..... ≧800 ≧800 ≧1500
Zero dispersion wavelength nm ≧1302,
≤1322 ..... ..... .....
Zero dispersion slope nm ≤0.091 ..... ..... .....
PMD Maximum Individual Fiber ≤0.2 ..... ..... .....
PMD Design Link Value Ps(nm2*km) ≤0.08 ..... ..... .....
Fiber cutoff wavelength λc nm ≧1180, ≤133 0 ..... ..... .....
Cable cutoff wavelength λcc nm ≤1260 ..... ..... .....
MFD 1310nm um 9.2±0.4 ..... ..... .....
1550nm um 10.4±0.8 ..... ..... .....
Numerical Aperture (NA) ...... 0.200±0.015 0.275±0.015 0.200±0.015
Step (mean of bidirectional measurement) dB ≤0.05 ≤0.10 ≤0.10 ≤0.10
Irregularities over fiber length
and point discontinuity dB ≤0.05 ≤0.10 ≤0.10 ≤0.10
Difference backscatter coefficient dB/km ≤0.03 ≤0.08 ≤0.10 ≤0.08
Attenuation uniformity dB/km ≤0.01 ....... ....... .......
Core diameter um ...... 50±1.0 62.5±2.5 50±2.5
Cladding diameter um 125.0±1.0 125.0±1.0 125.0±1.0 125.0±1.0
Cladding non-circularity % ≤1.0 ≤1.0 ≤1.0 ≤1.0
Coating diameter um 242±7 242±7 242±7 242±7
Coating/chaffinch concentrically error um ≤12.0 ≤12.0 ≤12.0 ≤12.0
Coating non circularity % ≤6.0 ≤6.0 ≤6.0 ≤6.0
Core/cladding concentricity error um ≤0.6 ≤1.5 ≤1.5 ≤1.5
Curl(radius) um ≤4 ..... ..... .....
Cable construction details:
Technical Parameters:
No Out Diameter Tight buffer
Weight Min. allowable Tensile Strength(N) Min. allowable Crush Load (N/100mm) Min. Bending Radius (MM) Storage
Diameter temperature
Core (MM) (MM) (KG) short term long term short term long term short term long term (℃)
2 3 0.6 1000 300 1000 500 20D 10D 40
4 4 0.6 1000 300 1000 500 20D 10D 40
6 4.5 0.6 1000 300 1000 500 20D 10D 40
8 5 0.6 1000 300 1000 500 20D 10D 40
12 6 0.6 1000 300 1000 500 20D 10D 40
24 10.5 0.6 1000 300 1000 500 20D 10D 40
Testing Lab:
No Device name No Device name
1 Optical time domain reflectometer (OTDR) 8 GNZV Cable Torsion Testing Machine
2 Fiber Polarization Mode Dispersion 9 GQNV Cable Flexing Testing Machine
3 Fiber Dispersion, Strain Tester 10 GJRV Cable Winding Testing Machine
4 High Low Temperature Test Chamber 11 GZDV Cable Vibration Testing Machine
5 Cable Impact Testing Machine 12 Cable Water Penetration Test
6 Cable Squash Tensile Testing Machine 13 Fusion Splicer
7 GWQV Cable Bending Tester 14 Cable Water Penetration Test Rig
Fiber Optic Cable Mechanical Performance Testing Laboratory:
1. Main Testing Type: Precision Test and Mechanical Test.
2. Precision Testing Machine: EXFO OTDR, EG&G PMD-440, CD-400.
3. Mechanical Performance Testing: Temperature, Impact, Tensile, Bending, Torsion, Flexing, Winding, Vibration, Water Penetration, Fusion Splicer, Water Penetration.
Application:
• Used in pigtails and patch cords;
• Used in optical connections in optical communication equipment rooms and optical distribution frames;
• Used in optical connections in optical apparatus and equipment.
Cable marking:
The cable sheath shall be marked with white characters at intervals of one meter with following information:
1 2 3 4 5 6
Brand name Fiber type and counts Cable type Name of manufacturer Country of origin Length marking
Part Number:
Items Name Part Number
6 core MM (50/125um) (OM3) Indoor Type Armored cable 6F-GJFJV-O3-AT
6 core MM (50/125um) (OM4) Indoor Type Armored cable 6F-GJFJV-O4-AT
Login To Comment