Armored Optical Fiber Cable [GYXTW]
1. Cable Construction:
1.1 Cross Sectional Diagram Product Photo:
1.2. Structure Specification:
ITEMS DESCRIPTION
Fiber Count 2-12F
Loose Tube OD (mm) 2.2±0.1
Material: PBT
Water Block Material Water blocking Compound
Armored Corrugation Steel tape
Strength Number(steel) 0.7mm*2
Sheath Thickness: Non. 1.7mm
Material: PE
OD of Cable (mm) 7.0
Net Weight (Kg/Km) 54
1. Fiber Identification:
NO. 1 2 3 4 5 6 7 8 9 10 11 12
Fiber Color Blue orange Green brown slate natural Red Black yellow violet pink Aqua
2. Optical Fiber:
2.1 Single Mode Fiber:
ITEMS UNITS SPECIFICATION
Fiber type G652D G657A
Attenuation dB/km 1310nm ≤ 0.36
1550nm ≤ 0.22
Chromatic Dispersion ps/nm.km 1310nm≤ 3.5
1550nm≤ 18
1625nm≤ 22
Zero Dispersion Slope ps/nm2.km ≤ 0.092
Zero Dispersion Wavelength nm 1300 ~ 1324
Cut-off Wavelength ( cc) nm ≤ 1260
Attenuation vs. Bending (60mm x100turns) dB (30mm radius,100ring) ≤ 0.1 @ 1625nm (10mm radius,1ring)≤ 1.5 @ 1625nm
Mode Field Diameter m 9.2 0.4 at 1310nm 9.2 0.4 at 1310nm
Core-Clad Concentricity m ≤ 0.5 ≤ 0.5
Cladding Diameter m 125±1 125±1
Cladding Non-circularity % ≤ 0.8 ≤ 0.8
Coating Diameter m 245±5 245±5
Proof Test Gpa ≥ 0.69 ≥ 0.69
1.2 Multi Mode Fiber:
ITEMS UNITS SPECIFICATION
62.5/125 50/125 OM3-150 OM3-300 OM4-550
Fiber Core Diameter μm 62.5±2.5 50.0±2.5 50.0±2.5
Fiber Core Non-circularity % ≤6.0 ≤6.0 ≤6.0
Cladding Diameter μm 125.0±1.0 125.0±1.0 125.0±1.0
Cladding Non-circularity % ≤2.0 ≤2.0 ≤2.0
Coating Diameter μm 245±10 245±10 245±10
Coat-Clad Concentricity μm ≤12.0 ≤12.0 ≤12.0
Coating Non-circularity % ≤8.0 ≤8.0 ≤8.0
Core-Clad Concentricity μm ≤1.5 ≤1.5 ≤1.5
Attenuation 850nm dB/km 3.0 3.0 3.0
1300nm dB/km 1.5 1.5 1.5
OFL 850nm MHz﹒KM ≥160 ≥200 ≥700 ≥1500 ≥3500
1300nm MHz﹒KM ≥300 ≥400 ≥500 ≥500 ≥500
The biggest theory numerical aperture / 0.275±0.015 0.200±0.015 0.200±0.015
2. Mechanical and Environmental Performance of the Cable:
NO. ITEMS TEST METHOD ACCEPTANCE CRITERIA
1 Tensile Loading Test #Test method:IEC 60794-1-E1
- Long-tensile load:300N
- Short-tensile load:600N
- Cable length:≥50m - Attenuation increment@1550nm:≤0.1dB
- No jacket cracking and fiber breakage
2 Crush Resistance Test #Test method:IEC 60794-1-E3
- Long load:300 N/100mm
- Short load:1000 N/100mm
- Load time:1 minutes - Attenuation increment@1550nm:≤0.1dB
- No jacket cracking and fiber breakage
3 Impact Resistance Test #Test method:IEC 60794-1-E4
- Impact height:1m
- Impact weigh: 450g
-Impact point:≥5
- Impact frequency:≥3/point - Attenuation increment@1550nm:≤0.1dB
- No jacket cracking and fiber breakage
4 Repeated Bending #Test method:IEC 60794-1-E6
- Mandrel diameter:20D (D = cable diameter)
- Subject weight:15kg
- Bending frequency:30 times
- Bending speed:2s/time - Attenuation increment@1550nm:≤0.1dB
- No jacket cracking and fiber breakage
5 Torsion Test #Test method:IEC 60794-1-E7
- Length:1m - Attenuation increment@1550nm:≤0.1dB
Part Number:
1. Single Mode Fiber:
Items Name Part Number
4 Core Armored Cable 4F-GYXTW-SM-AT
6 Core Armored Cable 6F-GYXTW-SM-AT
12 Core Armored Cable 12F-GYXTW-SM-AT
2. Multi Mode Fiber:
Items Name Part Number
4 core MM ( 50/125um) Inddor/Outdoor Armored cable 4F-GYXTW-MM-AT
4 core MM ( 50/125um) Inddor/Outdoor Armored cable 6F-GYXTW-MM-AT
4 core MM ( 50/125um) Inddor/Outdoor Armored cable 12F-GYXTW-MM-AT
Login To Comment